Swash™ Delux for Winery Sanitation and Barrel Cleaning

40 kW Swash DLX 40 Kilowatt (kW) Electrical Power Rating Carbon Steel Electric Steam Generator

40 kW Swash DLX, 40 Kilowatt (kW) Electrical Power Rating Carbon Steel Electric Steam Generator

Dimensions

Height34 in
Length30 in
Width26 in

Industry Standards

  • American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code
  • American Society of Mechanical Engineers (ASME) - CSD-1
  • Canadian Underwriters Laboratories (cUL)
  • Underwriters Laboratories (UL)
ASMEUL Listed

Standard Features

Built in accordance with A.S.M.E. Miniature Boiler CodeA.S.M.E. CSD-1 Compliant
UL Listed and labeled under UL 834Dual Pressure Controls (UL 353)
High Pressure Safety Reset. (UL 353)Low Level Cut-Off (LLCO) (UL 353)
100 psi Safety Relief Valve (A.S.M.E. Section I - V-Stamp)

Multiple Accessories Available

Specifications

BrandsElectro-Steam™
Electrical Power40 kW
Alternating Current (AC) Voltage1208 V, 230 V, 380 V, 415 V, 440 V, 480 V, 600 V
Phase23 Ø
Frequency50 Hz, 60 Hz
Boiler Horse Power4.0 bhp
Steam Capacity3138.02 lb/hr (62.6 kg/hr)
Water Consumption416.54 gal/hr (62.6 L/hr)
Gross British Thermal Units (BTU) Output5133,901 Btu/hr
Maximum Boiler Pressure100 psi
Operating Pressure (Factory Set at 85 Pound per Square Inch (psi))0 to 85 psi
Maximum Boiler Capacity6 gal
Boiler Fill Capacity4.2 gal
Boiler Material6Carbon Steel
Cabinet Material304 Stainless Steel
Plumbing Material7Brass, Carbon Steel (Schedule 40)

Amperage by Voltage (3Ø Phase)

208 VAC 240 VAC 380 VAC 415 VAC 440 VAC 480 VAC 600 VAC
111.0 A 104.8 A 60.8 A 55.6 A 52.5 A 48.1 A 38.5 A

Plumbing Connection Sizes

Water InletStandard Hose Adapter (Female)
Steam OutletSanitary Fitting for Accessory Connection
Safety Valve3/4 in. National Pipe Thread (NPT) (Female) - Safety Valve, Brass
Drain3/4 in. National Pipe Thread (NPT) (Female) - Ball Valve, Brass

Included Options

Single Service TransformerSupplied standard with all Swash steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120VAC 1Ø for the controls; with the option, only the one (1) primary high voltage supply is required.
Water Feed Booster PumpSupplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-80 psi water supply with a minimum flow rate of 2 gpm.

More Options

Spare Parts Package Includes18-Month Warranty (12-Month Standard)
(2) Electric Heaters and (2) Heater Gaskets
(2) Sight Glass Tubes and (4) Washers
(1) Pressure Control
(1) Contactor

Note

NoteA Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply plug the two attached wires into the PC-Board terminals labeled "Reset".
  • 1 Each generator is custom built to accommodate only one (1) costumer specific high voltage supply for the heaters. 120VAC 1Ø, 50/60Hz must also be supplied for the controls by the included Single Service Transformer.
  • 2 Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request.
  • 3 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feedwater must not exceed 140ºF.
  • 4 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feedwater must not exceed 140ºF.
  • 5 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feedwater must not exceed 140ºF.
  • 6 Wetted Surfaces. SCH 40 Carbon steel and Brass.
  • 7 Wetted Surfaces. SCH 40 Carbon steel and Brass.
Free Resource
Conveyor Belt Cleaning Solutions eBook cover

Conveyor Belt Cleaning Solutions for the Food & Beverage Industry

Learn how all-electric dry steam sanitation is transforming hygiene standards across food processing and beverage operations. Download our free industry guide.

Download Free eBook
Get in Touch

Ready to Find the Right Steam Solution?

Our engineering team is here to help you select the right generator for your application. Custom specifications, expert guidance, same-day part shipping.