Manufactured in the USA  ·  Est. 1952

S.S. LB 40-60 Electric Steam Generators

S.S. LB-40 (L) 40 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

S.S. LB-40 (L), 40 Kilowatt (kW) Electrical Power Rating High Pressure Electric Steam Generator

Dimensions

Length52 in
Width26 in
Height36 in

Minimum Clearance

Total Length96 in
Total Width58 in
Total Height45 in

Industry Standards

  • American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code
  • American Society of Mechanical Engineers (ASME) - CSD-1
  • Canadian Underwriters Laboratories (cUL)
  • Underwriters Laboratories (UL)
ASMEUL Listed

Standard Features

316L Stainless Steel on all Wetted SurfacesASME Certified
High Pressure Safety ResetUL Listed and labeled under UL 834
Dual Pressure Controls (UL 353)Low Level Cut-Off (LLCO)
Safety Relief Valve possessing the ASME V Mark

Recommended Options (Non-Standard)

Spare Parts PackageSingle Service Transformer

Specifications

BrandsElectro-Steam™
VariantLow Pressure
Electrical Power40 kW
Power Supply Voltage1208 VAC, 230 VAC, 380 VAC, 415 VAC, 440 VAC, 480 VAC, 600 VAC
Phase3
Frequency50 Hz, 60 Hz
Boiler Horse Power4.0 bhp
Steam Capacity2138.0 lb/hr (62.6 kg/hr)
Water Consumption16.54 gal/hr (62.6 L/hr)
Note for Water ConsumptionCalculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
Gross British Thermal Units (BTU) Output133,901 Btu/hr
Maximum Boiler Pressure15 psi
Operating Pressure0 to 11 psi
Maximum Boiler Capacity15 gal
Boiler Fill Capacity11 gal
Boiler Material3316L Stainless Steel
Cabinet Material304 Stainless Steel
Plumbing Material316L Stainless Steel (Schedule 40)

Amperage by Voltage (3Ø Phase)

208 VAC 240 VAC 380 VAC 415 VAC 440 VAC 480 VAC 600 VAC
111.00 A 104.80 A 60.80 A 55.60 A 52.50 A 48.10 A 38.50 A

Plumbing Connection Sizes

Water Inlet1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS)
Steam Outlet3/4" National Pipe Thread (NPT) (Female) - Ball Valve, 316L SS
Safety Valve3/4" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body.
Drain1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS)

Options

Spare Parts Package Includes18-Month Warranty (12-Month Standard)
(2) Electric Heaters and (2) Heater Gaskets
(2) Sight Glass Tubes and (4) Washers
(1) Pressure Control
(1) Contactor
Single Service TransformerSupplied standard with all portable steam generators, the Transformer steps down the primary high voltage supplied for the heaters, in order to provide 120 VAC1Ø for the controls; with the option, only the one (1) primary high voltage supply is required.
Manual Low Water Reset4Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production.
Portable Mounting IncludesWheels
Push Handle
Single Service Transformer Option
Water Feed Booster PumpThe minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm.
  • 1 Each Electro-Steam™ electric steam generator requires two (2) power supplies: One (1) primary high voltage supply and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate only one (1) customer specific high voltage supply for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
  • 2 Calculations are based off of a 212 ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60 ºF and 140 ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140 ºF.
  • 3 Wetted Surfaces.
  • 4 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply remove the jumper wire from the back of the Reset Button.
Free Resource
Conveyor Belt Cleaning Solutions eBook cover

Conveyor Belt Cleaning Solutions for the Food & Beverage Industry

Learn how all-electric dry steam sanitation is transforming hygiene standards across food processing and beverage operations. Download our free industry guide.

Download Free eBook
Get in Touch

Ready to Find the Right Steam Solution?

Our engineering team is here to help you select the right generator for your application. Custom specifications, expert guidance, same-day part shipping.