S.S. LB 100-240 Electric Steam Generators

S.S. LB-120 (L) 120 Kilowatt (kW) Electrical Power Rating Low Pressure Electric Steam Generator

S.S. LB-120 (L), 120 Kilowatt (kW) Electrical Power Rating Low Pressure Electric Steam Generator

Dimensions

Length51 in
Width30 in
Height37 in

Minimum Clearance

Total Length120 in
Total Width60 in
Total Height45 in

Industry Standards

  • American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code
  • American Society of Mechanical Engineers (ASME) - CSD-1
  • Canadian Underwriters Laboratories (cUL)
  • Underwriters Laboratories (UL)
ASMEUL Listed

Standard Features

316L Stainless Steel on all Wetted SurfacesASME Certified
High Pressure Safety ResetUL Listed and labeled under UL 834
Dual Pressure Controls (UL 353)Low Level Cut-Off (LLCO)
Safety Relief Valve possessing the ASME V Mark

Recommended Options (Non-Standard)

Spare Parts PackageSingle Service Transformer

Specifications

BrandsElectro-Steam™
VariantLow Pressure
Electrical Power120 kW
Power Supply Voltage1208 VAC, 230 VAC, 380 VAC, 415 VAC, 440 VAC, 480 VAC, 600 VAC
Phase23
Frequency50 Hz, 60 Hz
Boiler Horse Power12 bhp
Steam Capacity3414 lb/hr (187.79 kg/hr)
Water Consumption49.61 gal/hr (187.79 L/hr)
Gross British Thermal Units (BTU) Output401704 Btu/hr
Maximum Boiler Pressure15 psi
Operating Pressure0 to 11 psi
Note for Operating PressureFactory Set at 11 psi
Maximum Boiler Capacity26.5 gal
Boiler Fill Capacity22.0 gal
Boiler Material4316L Stainless Steel
Cabinet Material304 Stainless Steel
Plumbing Material316L Stainless Steel (Schedule 40)

Amperage by Voltage (3Ø Phase)

208 VAC 240 VAC 380 VAC 415 VAC 440 VAC 480 VAC 600 VAC
333.1 A
(166.5 A per Box)
314.3 A
(157.2 A per Box)
182.3 A
(91.2 A per Box)
166.9 A
(83.5 A per Box)
157.5 A
(78.7 A per Box)
144.3 A
(72.2 A per Box)
115.5 A
(57.7 A per Box)

Plumbing Connection Sizes

Water Inlet1/2" National Pipe Thread (NPT) (Female) - Street Elbow, 316L Stainless Steel (SS)
Steam Outlet1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS)
Safety Valve2" National Pipe Thread (NPT) (Female) - Safety Valve, 316L Stainless Steel (SS) Trim (Wetted Surfaces), Brass Body
Drain1" National Pipe Thread (NPT) (Female) - Ball Valve, 316L Stainless Steel (SS)

Options

Spare Parts Package Includes18-Month Warranty (12-Month Standard)
(2) Electric Heaters and (2) Heater Gaskets
(2) Sight Glass Tubes and (4) Washers
(1) Pressure Control
(1) Contactor
Single Service TransformerSupplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required.
Manual Low Water Reset5Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production.
Portable Mounting IncludesWheels
Push Handle
Single Service Transformer Option
Water Feed Booster PumpThe minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm.
  • 1 Electro-Steam™ 100-240 kW electric steam generators require three (3) power supplies: Two (2) primary high voltage supplies and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate two (2) supplies of only one (1) customer specific high voltage for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
  • 2 Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30 kW or lower are also available in Single Phase (1Ø) upon request.
  • 3 Calculations are based off of a 212 ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60 ºF and 140 ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140 ºF.
  • 4 Wetted Surfaces.
  • 5 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply remove the jumper wire from the back of the Reset Button.
Free Resource
Conveyor Belt Cleaning Solutions eBook cover

Conveyor Belt Cleaning Solutions for the Food & Beverage Industry

Learn how all-electric dry steam sanitation is transforming hygiene standards across food processing and beverage operations. Download our free industry guide.

Download Free eBook
Get in Touch

Ready to Find the Right Steam Solution?

Our engineering team is here to help you select the right generator for your application. Custom specifications, expert guidance, same-day part shipping.