LB 40-60 Electric Steam Generators

LB-40 (H) 40 Kilowatt (kW) Electrical Power Rating Electric Steam Generator

LB-40 (H), 40 Kilowatt (kW) Electrical Power Rating Electric Steam Generator

Dimensions

Length
(No Options)
52 in
Length
(with MAFD option)
55 in
Width
(No Options)
26 in
Width
(with MAFD option)
29 in
Height36 in

Minimum Clearance

Total Height45 in
Total Length96 in
Total Width58 in

Industry Standards

  • American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code
  • American Society of Mechanical Engineers (ASME) - CSD-1
  • Canadian Underwriters Laboratories (cUL)
  • Underwriters Laboratories (UL)
ASMEUL Listed

Standard Features

ASME CertifiedHigh Pressure Safety Reset
UL Listed and labeled under UL 834Dual Pressure Controls (UL 353)
Low Level Cut-Off (LLCO) (UL 353)Safety Relief Valve possessing the ASME V Mark

Recommended Options (Non-Standard)

Spare Parts PackageMotorized Automatic Flush and Drain (MAFD)
Single Service Transformer5-Micron Water Filter

Specifications

Brands Electro-Steam™
Variant High Pressure
Electrical Power 40 kW
Power Supply Voltage1 208 VAC, 230 VAC, 380 VAC, 415 VAC, 440 VAC, 480 VAC, 600 VAC
Phase 3
Frequency 50 Hz, 60 Hz
Boiler Horse Power 4.0 bhp
Steam Capacity2 138.0 lb/hr (62.6 kg/hr)
Water Consumption 16.54 gal/hr (62.6 L/hr)
Gross British Thermal Units (BTU) Output 133,901 Btu/hr
Maximum Boiler Pressure 100 psi
Operating Pressure 0 to 80 psi
Note for Operating Pressure Factory Set at 80 psi
Maximum Boiler Capacity 15 gal
Boiler Fill Capacity 11 gal
Boiler Material3 Carbon Steel
Cabinet Material 304 Stainless Steel
Plumbing Material Brass (Schedule 40), Carbon Steel (Schedule 40)

Amperage by Voltage (3Ø Phase)

208 VAC 240 VAC 380 VAC 415 VAC 440 VAC 480 VAC 600 VAC
111.00 A 104.80 A 60.80 A 55.60 A 52.50 A 48.10 A 38.50 A

Plumbing Connection Sizes

Water Inlet1/2" NPT (National Pipe Thread) (Female) - Y-Strainer, Brass
Steam Outlet3/4" NPT (National Pipe Thread) (Female) - Ball Valve, Brass
Safety Valve3/4" NPT (National Pipe Thread) (Female) - Safety Valve, Brass
Drain1" National Pipe Thread (NPT) (Female) - Ball Valve, Brass
Additional Drain (Motorized Automatic Flush and Drain (MAFD) Option Included)1" NPT (National Pipe Thread) (Female) - Motorized Valve, Brass

Options

Spare Parts Package Includes 18-Month Warranty (12-Month Standard)
(2) Electric Heaters and (2) Heater Gaskets
(2) Sight Glass Tubes and (4) Washers
(1) Pressure Control
(1) Contactor
Motorized Automatic Flush and Drain (MAFD) During Start-Up before steam pressure is accumulated, the Motorized Automatic Flush and Drain option cycles fresh water through the boiler for 0-300 seconds (Factory set for 180 seconds or three (3) minutes). As old water is drained out, fresh water will be cycled in. This drain valve will not open if boiler pressure exceeds 5 psi, and the electric heaters are locked out during flush cycle.
Single Service Transformer Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required.
5-Micron Water Filter 2-stage, 5-micron water filter installed into incoming water line to reduce sediment, dirt, rust, chlorine, and even odor from incoming water supply.
Manual Low Water Reset4 Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production.
Portable Mounting Includes Wheels
Push Handle
Single Service Transformer Option
Water Feed Booster Pump Supplied standard on any steam generator with an operating pressure higher than 15 psi. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-150 psi water supply with a minimum flow rate of 2 gpm.
  • 1 Each Electro-Steam™ electric steam generator requires two (2) power supplies: One (1) primary high voltage supply and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate only one (1) customer specific high voltage supply for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
  • 2 Calculations are based off of a 212ºF boiler feed-water temperature. Boiler feed-water temperatures that range between 60ºF and 140ºF, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140ºF.
  • 3 Wetted Surfaces
  • 4 A Manual Low Water Reset Button is supplied standard with every steam generator, but it is disabled. If this Reset Button is required as per your local boiler codes, simply plug the two attached wires into the PC-Board terminals labeled "Reset".
Free Resource
Conveyor Belt Cleaning Solutions eBook cover

Conveyor Belt Cleaning Solutions for the Food & Beverage Industry

Learn how all-electric dry steam sanitation is transforming hygiene standards across food processing and beverage operations. Download our free industry guide.

Download Free eBook
Get in Touch

Ready to Find the Right Steam Solution?

Our engineering team is here to help you select the right generator for your application. Custom specifications, expert guidance, same-day part shipping.