LG 10-40 Electric Steam Generators

LG-15 (S) 15 Kilowatt (kW) Rating SteamBath Electric Steam Generator

LG-15 (S) 15 kW Rating SteamBath Electric Steam Generator

Dimensions

Overall Height24 in
Overall Length27 in
Width
(No Options)
23 in
Width
(with MAFD option)
26 in
Width
(with SST option)
28 in
Width
(with MAFD & SST options)
31 in

Minimum Clearance

Total Height31 in
Total Length49 in
Total Width42 in

Industry Standards

  • American Society of Mechanical Engineers (ASME) - Boiler and Pressure Vessel Code
  • American Society of Mechanical Engineers (ASME) - CSD-1
  • Canadian Underwriters Laboratories (cUL)
  • Underwriters Laboratories (UL) 834
ASMEUL Listed

Standard Features

ASME CertifiedHigh Pressure Safety Reset
UL Listed and labeled under UL 834Dual Pressure Controls (UL 353)
Low Level Cut-Off (LLCO) (UL 353)Safety Relief Valve possessing the ASME V Mark

Included Options (Standard for SteamBaths)

Steam Solenoid (Steam Outlet)Temperature Control (Thermostat)
Diffuser Nozzle

Recommended Options (Non-Standard)

Spare Parts PackageMotorized Automatic Flush and Drain (MAFD)
Single Service Transformer5-Micron Water Filter

Specifications

BrandsElectro-Steam™
VariantSteamBath
Electrical Power15 kW
Power Supply Voltage1208 VAC, 230 VAC, 380 VAC, 415 VAC, 440 VAC, 480 VAC, 600 VAC
Phase23
Frequency50 Hz, 60 Hz
Boiler Horse Power1.5 bhp
Steam Capacity351.75 lb/hr (23.47 kg/hr)
Water Consumption6.20 gal/hr (23.47 L/hr)
Gross British Thermal Units (BTU) Output50,213 Btu/hr
Maximum Boiler Pressure15 psi
Operating Pressure (Factory Set at 11 Pound per Square Inch (psi))0 to 11 psi
Maximum Boiler Capacity6 gal
Boiler Fill Capacity4.2 gal
Boiler Material4Carbon Steel
Cabinet Material304 Stainless Steel
Plumbing MaterialBrass (Schedule 40), Carbon Steel (Schedule 40)

Amperage by Voltage (3Ø Phase)

208 VAC 240 VAC 380 VAC 415 VAC 440 VAC 480 VAC 600 VAC
41.60 A 39.30 A 22.80 A 20.90 A 19.70 A 18.00 A 14.40 A

Plumbing Connection Sizes

Water Inlet3/8" NPT (National Pipe Thread) (Female) - Y-Strainer, Brass
Steam Outlet3/8" NPT (National Pipe Thread) (Female) - Steam Solenoid, Brass
Safety Valve3/4" NPT (National Pipe Thread) (Female) - Safety Valve, Brass
Drain3/4" National Pipe Thread (NPT) (Female) - Ball Valve, Brass
Additional Drain (Motorized Automatic Flush and Drain (MAFD) Option Included)3/4" NPT (National Pipe Thread) (Female) - Motorized Valve, Brass

Included Options

Steam Solenoid (Steam Outlet) Supplied standard on all SteamBath models, the Steam Solenoid controls the flow of steam from the steam generator into a room or area (most commonly a steam room). This Normally Closed (NC), 120 VAC, 3/8" NPT, Brass Steam Solenoid opens when it receives 120 VAC from the Temperature Control.
Temperature Control (Thermostat) Supplied standard on all SteamBath models, the Temperature Control measures and maintains the temperature of a room or area (most commonly a steam room) by electronically controlling the Steam Solenoid. This Option is supplied standard with all SteamBath Models.
Diffuser Nozzle Supplied standard on all SteamBath models, the Diffuser Nozzle is a Slotted Stainless Steel Pipe Cap. Diffuser Nozzle has a 1/2" Female NPT connection and the flat fan shaped steam jet leaves the nozzle at 90º. This Option is supplied standard with all SteamBath Models.

Options

Spare Parts Package Includes 18-Month Warranty (12-Month Standard)
(2) Electric Heaters and (2) Heater Gaskets
(2) Sight Glass Tubes and (4) Washers
(1) Pressure Control
(1) Contactor
Motorized Automatic Flush and Drain (MAFD) During Start-Up before steam pressure is accumulated, the Motorized Automatic Flush and Drain option cycles fresh water through the boiler for 0-300 seconds (Factory set for 180 seconds or three (3) minutes). As old water is drained out, fresh water will be cycled in. This drain valve will not open if boiler pressure exceeds 5 psi, and the electric heaters are locked out during flush cycle.
Single Service Transformer Supplied standard with all portable steam generators, the Single Service Transformer steps down the primary high voltage to provide 120 VAC Single Phase (1Ø) to the controls; with this option, only the one (1) primary high voltage supply is required.
5-Micron Water Filter 2-stage, 5-micron water filter installed into incoming water line to reduce sediment, dirt, rust, chlorine, and even odor from incoming water supply.
Manual Low Water Reset5 Manual Low Water Reset trips if the electric heaters shut-off because of a low water condition. Reset must be manually pressed to resume steam production.
Water Feed Booster Pump The minimum requirement for your water pressure is the operating pressure +25 psi; if your water pressure is below this requirement, this option must be added. The Water Feed Booster Pump increases your incoming water pressure to overcome the operating pressure of the steam generator. The Pump requires a 5-80 psi water supply with a minimum flow rate of 2 gpm.

More Options

Dual Room Controls Dual Room Controls provides the means to independently measure and maintain the temperature of a two (2) separate rooms or areas (most commonly a men’s and a women's steam room) With this option, two (2) Steam Solenoids, two (2) Temperature Controls, and two (2) Diffuser Nozzles are supplied.
  • 1 Each Electro-Steam™ electric steam generator requires two (2) power supplies: One (1) primary high voltage supply and one (1) secondary 120 VAC 1Ø, 50/60 Hz supply. Each generator is custom built to accommodate only one (1) customer specific high voltage supply for the heaters. 120 VAC 1Ø, 50/60 Hz must also be supplied for the controls, unless the Single Service Transformer option is added.
  • 2 Three Phase (3Ø) primary high voltage is standard, but steam generators with a power rating of 30kW or lower are also available in Single Phase (1Ø) upon request.
  • 3 Calculations are based off of a 212 °F boiler feed-water temperature. Boiler feed-water temperatures that range between 60 °F and 140 °F, are approximately 80% to 90% of the calculated values shown. Boiler feed-water must not exceed 140 °F.
  • 4 Wetted Surface.
  • 5 Manual Low Water Reset is supplied standard with every boiler, but it is not hooked up. If this reset is required as per your local boiler codes, simply plug the two attached wires into the PC-Board terminals labeled "Reset".
Free Resource
Conveyor Belt Cleaning Solutions eBook cover

Conveyor Belt Cleaning Solutions for the Food & Beverage Industry

Learn how all-electric dry steam sanitation is transforming hygiene standards across food processing and beverage operations. Download our free industry guide.

Download Free eBook
Get in Touch

Ready to Find the Right Steam Solution?

Our engineering team is here to help you select the right generator for your application. Custom specifications, expert guidance, same-day part shipping.